Wellview Universal Group
YSTE-GC7860 Gas Chromatography
Request photos and details of the available configuration.
Request photos on WhatsAppRequest configuration, accessories, documentation and supply terms for this model.
Supplier technical information: confirm the configuration before purchasing.
The YSTE-GC7860 can be equipped with a liquid automatic sampler, which uses control software to control various parameters. This will bring better repeatability and improve work efficiency, while eliminating errors caused by manual sampling. Features 1.8-inch touch screen. 2.Gas circuit manually and full electronic gas circuit (EPC/EFC, control is optional,networking communication (Ethernet interface lEEE802.3),computer online full control operation. 3.Electronic gas circuit (EPC/EFC) control mode EPC electronic gas circuit control precision is 0.01mL/min or 0.01Kpa, which ensures better retention time reproducilbility and more consistent and reliable results EPC working mode: constant current, constant voltage, shunt mode Program pressure control: 4 stage EPC working gases: N2, H2, Air, He, Ar EPC control range: pressure 0~0.6kpa flow 0~100sccm or 0~500sccm EPC control accuracy: pressure 0.01Kpa; Flow rate of 0.01sccm 4.Support high-speed heating, the maximum rate of 80°C/min; Suitable for rapid analysis 5.Could be up to 450°C, suitable for high boiling point the analysis of the sample 6.Support double oven and double rear door opening mode 7.Oven temperature increment 1°C, the accuracy of + /-0.01°C, is close to high-grade imported similar products 8.External events: 6-way. auxiliary control 2-way. 9.Diversified injection system; Packed column injection, capillary S/SL injection, valve injection, automatic liquid injection,automatic headspace injection, splitting injection, thermal desorption injection, purge and capture injection are optional 10.Special customized valve system can help users complete complex multidimensional chromatographic analysis tasks. Plus series is a multi-purpose gas chromatography specially designed for multidimensional application analysis and online analysis. 11.Rich detector types, up to three detectors can be installed: TCD, HTCD, uTCD, FID, FPD, ECD, NPD, ZD, PDHID, PID, AID 12.The program supports multiple flow path sample selection MPV system, with automatic identification valve number,automatic cascade judgment, automatic reset, valve position selection, valve position analysis memory function, up to 32 support sample flow path selection 13.Unique network remote transmission and control functions, unattended analysis, decentralized monitoring, centralized control. 14.The data can be connected to DCS system to complete the statistics, analysis and monitoring of chromatographic component content and improve the automation level of production process control 15.Temperature control index 16.Temperature control circuit number: 8 17.Oven temperature index Oven temperature range: room temperature of 4 °C ~ 450°C (increment 1°C) Oven temperature control precision, better than ±0.01°C Oven temperature programming Rising order: 16 order Rising rate setting: 0.1 ~39°C/min (ordinary type); 0.1~80°C/min (high-speed type) Constant temperature time of each order: 0~999min (increment: 0.1min) Programmed cooling: 260°C to 50°C only need 6 minutes 18.Sample injector, detector, thermal conductivity pool, methane reformer temperature index; 19.Range of temperature: Room temperature of 4°C~ 450°C (increment 1 °C) The accuracy of temperature control: better than ±0.01°C Detector FID The collecting pole adopts the original cylindrical structure and quartz nozzle Limit of detection:≤3x10-12g/s Baseline Noise: 5x10-14A Baseline Drift: ≤1x10-13A/30min Linear: ≥107 Autoignition TCD Adopt semi-diffused structure Constant current control mode is adopted for power supply Sensitivity:S≥3000mv.ml/mg HTCD High sensitivity thermal conductivity detector S≥10000mv.ml/mg, Digital amplification 1, 2, 4, 8 times optional Baseline Noise:≤10μv Baseline Drift:≤30μv/30min Linear:≥105 Carrier gas velocity stability:≤1% Capillary column connecting parts are optional ECD Limit of detection:≤1x10-14g/s Linear range: 104 Source: Nj63 FPD Limit of detection: 5x-12g/s(S) (S in methyl parathion) 5x10-13g/s (P) (P in methyl parathion) Linear range:105(P)103(S) Maximum service temperature: 350°C Detection Method: Air-hydrogen flame spectrometry Optional detector: Top photomultipier Multiplier voltage: Max--700V NPD Limit of detection: (N)≤5x10-12g/s (P)≤5x10-12g/s
Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.
Request a quote ↗