Wellview Universal Group
X-ray dose YSX1628
Request photos and details of the available configuration.
Request photos on WhatsAppRequest configuration, accessories, documentation and supply terms for this model.
Supplier technical information: confirm the configuration before purchasing.
High Performance YSX1628 X/Y ray Radiation Dosimeter The portable radioactive contamination dosimeter is a wearable device,which id produced with the functionally powerful MCU technology. It is mainly for testing x-ray and y-ray, and directly reading the dose and dose rate. In the scope of its measurement, the alarming threshold can be fixed or pre-set.When the threshold is overrun or block dose happens, the meter will send out light and sound alarm signals. As a wearable device, it features small size and low power. It is widely used in such fields as non-destructive flaw detection, nuclear power station,nuclear submarine, isotope application, and cobalt therapy in hospital. Features: 1. High sensitivity, and response to environmental background. 2. Measuring both dose and dose rate, and providing various alarming signals. 3. Low power, small size, and easy use. Technical parameter: 1. Detector:GM counting tube, measuring X-ray and γ-ray; 2. Display screen: 4 numbers LCD; 3. Measuring range: Accumulated dose equivalent: Hp (10) 0.0usv ~ 99.99msv; Dose equivalent rate: Hp (10) 0.1usv / h ~ 99.99msv / h; 4. Response time: 3.6S-36S; 5. Measuring rate response: <±20%(1usv/h~99.99msv/h) 6. Energy response: <±30%(50KeV~1.3MeV) 7. Relative inherent error: <±20%(137Cs). 8. Alarm function and alarm valve value: Measuring rate and accumulated dose can preset alarm valve value in the measuring range. The fixed alarm valve value as follows: 1).Accumulated dose: Per increase 0.1usv, a short noise and light each time: ≥50 usv, sound-light alarm5s,"ALARM"display. 2.) Measuring rate: ≥25usv/h,sound-light alarm is about 6s,"ALARM" display. 3. )Clogging alarm: when counting tube clogged, alarm continuously, "ALARM" display, alarm sound intensity is about 80 decibels at the 30 cm. 9. The battery under voltage indicates: when Battery voltage <2.7 +/- 0.05 Vs, the instrument displays under voltage symbol "LOBAT". It still can work for more than 24 hours in the lower radiation place after under voltage symbol appears. 10. Battery and consumption: AAA type 1.5 V alkaline battery(7#battery), consumption<2mw, continuous service: 720 hours. 11. Temperature characteristic: < ±10%- 10degree -- +50degree. 12. Temperature features: < ± 10% 95% GH (+ 35%) 13. Size: 55(width)×92(length)×18(thickness). 14. Weight: <75g,including battery <98g.
Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.
Request a quote ↗