Operation Room Biphasic Defibrillator YS-8000D

Request configuration, accessories, documentation and supply terms for this model.

Supplier technical information: confirm the configuration before purchasing.

A biphasic defibrillator room YS-8000D
Physical characteristics:
Main Unit: Portable
Dimensions:L320xW205xH410
Weight:9.5kg
Technical specifications
DEFIBRILLATOR
(1)Defibrillator type Manual, Synchronized, Asynchronized,
(2)Out put waveform Biphasic technology
(3)Energy accuracy ∠+1%
(4)Energy selection 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joule (nominal ata resistance of 50)
(5)Charging time Maximum 8 seconds to 360 Joules
(6)Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated)
Power requirements.
(a)AC Power supply 110V, 60 Hz /220V, 50 Hz
(b)Vehicle Voltage DC 12V
Internal Battery Backup
(1)Battery type Rechargeable lead-acid battery
(2)Charging time Time-Minimum of 4 hours for full charging
(3)Battery charging During AC Power Supply operation of the device.
(4)Charging /Low Battery Indication Red LED
(5)Battery Capacity 100% of the battery will provide 120 mins of monitoring;
and 30 discharges at 360 joules.
Display
-LED Dimensions 7’diagonal {155mm*88mm} which is easily read from a distance.
-Type High resolution true-color graphic LED
-Resolution 480X234
- Provide cardioversion facilities with waveform annotated on the screen
- Display 4 seconds of ECG at 25mm/sec, ECG selectable from leads I, II, III when used
with a 3-lead cable, and I, II, III aVL, aVR, aVF and V when used with a 5-lead cable.
- Display prompts, waveform settings, battery status, event summary and fault codes.
Energy selected is displayed by push button under the screen.
ECG
ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical
knife and defibrillation
Respiration
Measurement method: Thoracic impedance
Standard parameter & configuration
ECG/ RESP/DEFIBRILLATOR
-Provide audible and visual alarms for heart rate violations, VF and VT.
-Provide a strip printer which annotates waveforms, events, time code
-Have a 5-lead patient cable as an option to a 3-lead cable.
-Supplied with external re-usable paddles and packs of paper rolls for the printer.

Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.