12.1 Inch Multi-parameter Patient Monitor YSF8

Product image coming soon12.1 Inch Multi-parameter Patient Monitor YSF8

Request photos and details of the available configuration.

Request photos on WhatsApp

Request configuration, accessories, documentation and supply terms for this model.

Supplier technical information: confirm the configuration before purchasing.

12.1 inch multi-parameter patient monitor YSF8
1. 12.1' color TFT LCD screen supports display max. 9 waveforms
2. Personated voice reminding alarm; Visual On-display and integrated alarm light
3. Real time S-T segment analysis, pace detection and arrhythmia analysis
4. Drug calculation and titration table
5. Extended advance function: 2IBP, IOC, EtCO2, Multi-Gas/ O2
6. Suitable for monitoring adult, pediatric and neonatal patient.
7. Display mode: Standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG.
8. Supporting storage of 720 hours patient data, 1000 NIBP records and 500 alarm event
9. External lead-acid battery
10. Multi-language:Chinese, English, Spanish,Portuguese, Russian, French, German, Czech,
11. Denish, Dutch, Finland, Italian, Porlish, Turkish
YSF8's Standard Configuration:
Anti-glare screen, Rechargeable lead-acid battery, 3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
YSF8's Optional Configuration:
2IBP, Nellcor SpO2, Depth of Anesthesia Monitoring Module, EtCO2 (Main-stream/Side-stream/ Micro-stream CO2), Multi-Gas/ O2, Pitch Tone
VGA, Thermal printer (50 mm)
Pediatric / neonatal accessories: reusable NIBP cuff & SpO2 probe; disposable NIBP cuff & SpO2 probe
Central Monitoring System
Physical Specifications
Dimension and weight
Dimension
340mm(W)*280mm(H)*130mm(D)
Weight
standard configuration: 4 kg
Operation environment
Power requirements
AC 90-300V, 50/60HZ, 60W
Power
90VA
Temperature
0-40℃
Humidity
0-93% non-condensing
Safety
Meet the requirements of IEC60601 series
Patient range
Adult, neonate and pediatric patients
Performance Specification
Display
12.1’ (800 x 600 pixel) color TFT LCD screen, support external VGA(option). rolling and refreshing waveform display
Display mode
Standard, large font, NIBP trend, trend table, full lead ECG, Oxy CRG.
Interface
Parameter cable interface
AC power input socket
Network interface
External VGA interface for connection of alternate display
Battery
1 internal rechargeable lead-acid battery, 2.0Ah 12V
Alarm indicator
Visual on-display and integrated alarm light
Audible alarm and personated voice reminding alarm
Data storage
720 hours monitoring data
10000NIBP records storage
500 alarm event.
Printer
Built-in 50mm thermal printer (option),
3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s
print width:50mm
Net working
Support connection to central monitoring station through LAN (TCP/IP) or wireless connection
ECG
Leads type
3/5-lead : I, II, III, aVR, aVL, aVF, V
Sweep speed
12.5mm/s, 25mm/s,50mm/s
Gain selection
×0.25, ×0.5, ×1, ×2
ECG waveform
3 channels
Operation mode
Diagnostic, monitor, surgery
Heart rate range
15 -350bpm
Accuracy
1bpm or ±1% whichever is great
Alarm range
Audible and visual alarm, adjustable
ST/ arrhythmia
Real time S-T segment detection, pace detection and arrhythmia analysis
Protection
Against electrosurgical interference and defibrillation
Respiration (RESP)
Method
Thoracic impedance
Operation mode
Auto/manual
Measurement range
Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM
Apnea alarm
Yes
Alarm
Yes, audible and visual alarm ,alarm events recallable
NIBP
Method
Automatic oscillometric
Operation mode
Manual/Automatic/STAT
Auto measure time
Adjustable
Measurement unit
mmHg / kPa selectable
Test interval
1-480 minutes
Measurement range
Adult: 0-300 mmHg ;
Child: 0-240 mmHg ;
Infant: 0-150 mmHg
Over-pressure protection
Double safety protection
Accuracy of blood pressure measurement
The mean error shall be less than±5mmHg
the standard deviation shall be less than 8mmHG
Resolution
1 mmHg
SpO2
Measurement range
0%-100%
Resolution
1%
Accuracy
± 2% (70-100%, adult / pediatric, non-motion)
±3% (70-100%, neonate, non-motion )
±3% (70-100%, adult/pediatric/neonate, motion )
0-69% unspecified
Alarm range
1-100%
Pulse rate
Pulse range:
0-350bpm
Accuracy:
±3bpm(non-motion)
± 5bpm (motion)
Temperature (TEMP)
TEMP range
0-50℃
Resolution
0.1 ℃
Accuracy
±0.1℃ (excluding the sensor)
Channel
Dual-channel. provide T1; T2 and
IBP
Measurement range
-50-360mmHg
Channel
2 channels
Pressure transducer
Sensitive: 5u V/V mmHg
Impedance range: 300-3000 Ω
Pressure names
ART, PA, CVP, RAP, LAP, ICP, P1, P2
Alarm range
-10-300 mmHg
PR from IBP
Range & Accuracy:
25-200bpm ±1bpm or ±1bpm which is greater
201-350bpm ±2%
Resolution :
1bpm
Depth of Anesthesia (BIS)
EEG sensitivity
+/- 475μV
Noise
< 2uVp-p (1-150 Hz)
CMRR
> 100 dB
Input impedance
> 50mohm
Sample rate
1024 samples/s, 16 bits

Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.