12.1 Inch Multi-parameter Patient Monitor YSF8
Request photos and details of the available configuration.
Request photos on WhatsAppRequest configuration, accessories, documentation and supply terms for this model.
Supplier technical information: confirm the configuration before purchasing.
12.1 inch multi-parameter patient monitor YSF8 1. 12.1' color TFT LCD screen supports display max. 9 waveforms 2. Personated voice reminding alarm; Visual On-display and integrated alarm light 3. Real time S-T segment analysis, pace detection and arrhythmia analysis 4. Drug calculation and titration table 5. Extended advance function: 2IBP, IOC, EtCO2, Multi-Gas/ O2 6. Suitable for monitoring adult, pediatric and neonatal patient. 7. Display mode: Standard, Large Font, NIBP Trend, Trend Table, Full lead ECG, Oxy CRG. 8. Supporting storage of 720 hours patient data, 1000 NIBP records and 500 alarm event 9. External lead-acid battery 10. Multi-language:Chinese, English, Spanish,Portuguese, Russian, French, German, Czech, 11. Denish, Dutch, Finland, Italian, Porlish, Turkish YSF8's Standard Configuration: Anti-glare screen, Rechargeable lead-acid battery, 3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature YSF8's Optional Configuration: 2IBP, Nellcor SpO2, Depth of Anesthesia Monitoring Module, EtCO2 (Main-stream/Side-stream/ Micro-stream CO2), Multi-Gas/ O2, Pitch Tone VGA, Thermal printer (50 mm) Pediatric / neonatal accessories: reusable NIBP cuff & SpO2 probe; disposable NIBP cuff & SpO2 probe Central Monitoring System Physical Specifications Dimension and weight Dimension 340mm(W)*280mm(H)*130mm(D) Weight standard configuration: 4 kg Operation environment Power requirements AC 90-300V, 50/60HZ, 60W Power 90VA Temperature 0-40℃ Humidity 0-93% non-condensing Safety Meet the requirements of IEC60601 series Patient range Adult, neonate and pediatric patients Performance Specification Display 12.1’ (800 x 600 pixel) color TFT LCD screen, support external VGA(option). rolling and refreshing waveform display Display mode Standard, large font, NIBP trend, trend table, full lead ECG, Oxy CRG. Interface Parameter cable interface AC power input socket Network interface External VGA interface for connection of alternate display Battery 1 internal rechargeable lead-acid battery, 2.0Ah 12V Alarm indicator Visual on-display and integrated alarm light Audible alarm and personated voice reminding alarm Data storage 720 hours monitoring data 10000NIBP records storage 500 alarm event. Printer Built-in 50mm thermal printer (option), 3 traces, print speed 12.5mm/s & 25mm/s & 50mm/s print width:50mm Net working Support connection to central monitoring station through LAN (TCP/IP) or wireless connection ECG Leads type 3/5-lead : I, II, III, aVR, aVL, aVF, V Sweep speed 12.5mm/s, 25mm/s,50mm/s Gain selection ×0.25, ×0.5, ×1, ×2 ECG waveform 3 channels Operation mode Diagnostic, monitor, surgery Heart rate range 15 -350bpm Accuracy 1bpm or ±1% whichever is great Alarm range Audible and visual alarm, adjustable ST/ arrhythmia Real time S-T segment detection, pace detection and arrhythmia analysis Protection Against electrosurgical interference and defibrillation Respiration (RESP) Method Thoracic impedance Operation mode Auto/manual Measurement range Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM Apnea alarm Yes Alarm Yes, audible and visual alarm ,alarm events recallable NIBP Method Automatic oscillometric Operation mode Manual/Automatic/STAT Auto measure time Adjustable Measurement unit mmHg / kPa selectable Test interval 1-480 minutes Measurement range Adult: 0-300 mmHg ; Child: 0-240 mmHg ; Infant: 0-150 mmHg Over-pressure protection Double safety protection Accuracy of blood pressure measurement The mean error shall be less than±5mmHg the standard deviation shall be less than 8mmHG Resolution 1 mmHg SpO2 Measurement range 0%-100% Resolution 1% Accuracy ± 2% (70-100%, adult / pediatric, non-motion) ±3% (70-100%, neonate, non-motion ) ±3% (70-100%, adult/pediatric/neonate, motion ) 0-69% unspecified Alarm range 1-100% Pulse rate Pulse range: 0-350bpm Accuracy: ±3bpm(non-motion) ± 5bpm (motion) Temperature (TEMP) TEMP range 0-50℃ Resolution 0.1 ℃ Accuracy ±0.1℃ (excluding the sensor) Channel Dual-channel. provide T1; T2 and IBP Measurement range -50-360mmHg Channel 2 channels Pressure transducer Sensitive: 5u V/V mmHg Impedance range: 300-3000 Ω Pressure names ART, PA, CVP, RAP, LAP, ICP, P1, P2 Alarm range -10-300 mmHg PR from IBP Range & Accuracy: 25-200bpm ±1bpm or ±1bpm which is greater 201-350bpm ±2% Resolution : 1bpm Depth of Anesthesia (BIS) EEG sensitivity +/- 475μV Noise < 2uVp-p (1-150 Hz) CMRR > 100 dB Input impedance > 50mohm Sample rate 1024 samples/s, 16 bits
Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.
Request a quote ↗