Wellview Universal Group
Mobile ICU Ventilator SH300
Request photos and details of the available configuration.
Request photos on WhatsAppRequest configuration, accessories, documentation and supply terms for this model.
Supplier technical information: confirm the configuration before purchasing.
Features · 10.4" TFT color screen · Easy setting by navigator wheel knob and touch key · Wide choice of ventilation modes including CPAP, APRV, BIPAP · Flow and pressure trigger · Static compliance and resistance monitor · PEEP, P-V loop, V-F loop · Three-level visual and audible alarm, with concise words describing problems · Advanced built-in electronic air-oxygen mixing device · Durable and accurate built-in flow sensor · Integrated expiration valve, easy to be sterilized · Backup apnea ventilation · Auto nebulizer · Built-in battery · CE certified Specifications Specifications Ventilator setting Ventilation mode: VCV, PCV, PSV, SIMV-V, SIMV-P, SPONT, CPAP, backup apnea ventilation, APRV, BIPAP (optional) Tidal volume: 50 ~ 1500ml Breath rate: 1~100bpm SIMV breath rate: 1~40bpm Inspiratory time: 0.1~12s Pause time: 0~4.8s Pressure trgger sensitivity: (PEEP-20cmH2O)~PEEPcmH2O Flow trigger sensitivity: 1~20LPM PSV: 0~70cmH2O High pressure: 1~80cmH2O Low pressure: 0~79cmH2O Waveforms displayed: p-t, F-t, p-t, p-g, p.g, p.g, p.g. PEEP/CPAP: 0~50cmH2O FiO2: 21~100% Psupp: 0~70cmH2O Pinsp: 5~70cmH2O Thigh: 0.1~30s Tlow: 0.5~30s Phigh: 5~70cmH2O Plow: 0~50cmH2O Alarm silence: ≤120s Parameters monitored: VTI, VTE, MV, MVspn, f, fspn, FiO2, Ppeak, Pmean, Pplat, PEEP, Pmin, Compliance, Resistance Interface: RS232, VGA Assist functions Freeze: Freeze current screen and suspend real-time data Insp hold: 15s max Exp hold: 15s max O2 suction: 100% O2 for 2 munites Manual insp Alarms MV-upper limit: 0~99L MV-lower limit: 0~99L Paw-upper limit: 0.1~8KPa Paw-lower limit: 0~7.9KPa VTE-upper limit: 0.05~2.00L, OFF Rate-upper limit: 0~100bpm Rate-low limit: 0~99bpm Tapnea: 15~60s FiO2-upper limit: 21~100% FiO2-lower limit: 21~99% Main failure, Battery low, Battery discharged, Air/O2 supply down, Circuit occlusion Power and environmental Power: AC110~240V, 50~60Hz, DC 12V, 4.4AH Power comsumption: 65VA Driven mode: Pneumatically driven, electronically controlled Air/O2 supply: Pressure 0.28~0.6MPa >50L/min Temperature: Operation 10~40°c; Storage -20~55°c Relative humidity: Operation ≤80%, non-condensing; Storage ≤93%, non-condensing Atmospheric pressure: Operation 70~106KPa Order information Option: Compressor Accessories: Power cord, Gas pipeline, Patient circuit, Face mask, Humidifier, Support arm Option ☆12.1 inch TFT touch screen
Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.
Request a quote ↗