High-grade Type Medical Mobile Anesthesia System With Ventilator YSAV603B
YSAV603B Anesthesia Machine, with its ergonomic design, integrates a concise and smooth structure and high mobility. The microcomputer-controlled Ventilator adopts exported sensors and other components. Its scientific and proper design as well as rigorous production process demonstrate the inner quality: mechanical ventilation is made secure and visible by the folded respiratory bellows, and the security of air supply is guaranteed by pneumatic transmission and measurement system. With multiple
modern technologies applied, the Anesthesia Machine is both outstanding in performance and versatile in functions.
1.The Ventilator adopts microcomputer control with high-definition TFT color LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
2.The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
3.High-definition four-tube flowmeter, designed with stoppers for oxygen and nitrous oxide to control the output oxygen concentration.
4.Reliable pneumatic transmission system.
5.Economic and proper configuration of technologies, optional as required by the Customer.
6.Modularized design and upgrading. Upgrading is available as required by the Customer.
YSAV603B Specification
Main body
High-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of application
adult, child
Gas source
O2: 0.27 ~ 0.55MPa N2O: 0.27 ~ 0.55MPa
Flow meter
O2: 0.1~1.0L/min 1.1~10L/min
N20: 0.1~1.0L/min 1.1~10L/min
O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
Flow rate of rapid oxygen supply
25~75L/min
Low oxygen pressure alarm
There will be sound alarm when the oxygen
pressure < 0.2MPa
Vaporizer
it has the function of automatic compensation based on
pressure, temperature, and flow rate. The regulation
range of evaporator concentration is 0~5 vol%. Among
Halothane,Enflurane, Isoflurane and Sevoflurane, one
can be chosen for application as required by the
customer. And vaporizers that are imported with original
packaging are also available.
Respiratory circuit
working mode: all-close, semi-close, semi-open
releasing pressure: 0.5~7 kPa
Respiratory Bellows
bellows for adults, bellows for children
tidal volume range: 0 ~ 1,500 ml
Ventilator
Display mode
High-definition TFT color LCD screen display
Ventilation mode
IPPV, SIPPV, SIMV, PEEP, MANUAL,
SIGH, (IMV, VCV, PCV)
Ventilation parameters
Tidal volume
50~1500 ml (20~1500 ml)
Rate
1~99 bpm
SIMV rate
2~20 bpm
I:E
2:1~1:8 (4:1~1:8)
Inspiratory trigger pressure
-1.0~2.0Kpa
PEEP
PressureRange
0~2.0Kpa
1.0~6.0Kpa
SIGH
1.5 times the inspiratory time (70-150 adjustable)
Inspiratory platform
0~50%
Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance,flow-volume oop,pressure-volume loop)
Monitoring of oxygen concentration
21%~100%
Security Alarm System
Oxygen Concentration alarm
upper limit setting range 21%~100%
low limit setting range 10%~80%
Airway pressure alarm
upper limit setting range 0.3~6.0 kPa
low limit setting range 0.2~5.0 kPa
Per-minute ventilation volume alarm
upper limit setting range 3.0~30L/min
low limit setting range 1.0~10L/min
Sustained high-pressure alarm
it will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm
it will give sound and light alarm if there
is no tidal volume input for 15 seconds
Power alarm
Power
AC 220V±10% 50Hz±1Hz(UPS, Storage battery)
(Mechanical Arms)(End-expiratory CO2 monitoring)
Items within brackets are optional.

Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.