Wellview Universal Group
LCD Display Mobile Ventilator Machine YSAV90B
Request configuration, accessories, documentation and supply terms for this model.
Supplier technical information: confirm the configuration before purchasing.
LCD display mobile ventilator machine YSAV90B SPECIFICATIONS Physical specifications Display 10.4'' LCD Display Mode: pneumatically powered and electrically controlled system Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions Technical Specifications: Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa safety valve <12.5 kPa Respiratory Rate 1 ~ 99 bpm gas concentration output 21% ~ 100% adjustable Maximum Minute ventilation ≥18L / min modes of ventilation A/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUAL Ventilator compliance ≤30 Ml/kPa PEEP: 0 ~ 1.0 kPa Ptr: -10 ~ 10 hPa IMV frequency: 1~20 bpm I/E Ratio: 4:1~1:4, Has the inverse ratio ventilation Tidal Volume Setting Range: 50 ~ 1500ML Display Range: 0 ~ 2000ml and resolution ratio: 10ml Inspiratory Plateau: 0~1s Maximum Safety Pressure ≤ 6.0kPa Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point Pressure limit range: 1.0~ 6.0kPa Airway pressure alarm: Audible and visual and with yellow and red color indicating Lover: 0.1 kPa ~ 6.0 kPa and Upper: 0 ~ 5.0 kPa ±0.2 kPa Ventilation Volume alarm: ≥ 18L/ MIN Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator. Operating conditions Ambient temperature: 10 ~ 40oC Relative humidity: no higher than 80 % Atmospheric pressure: 860 hPa ~ 1060 hPa Power requirement: 100-120 Vac, 50/60 Hz; Attention: the AC power supply used for the anesthesia machine must be well grounded. Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. Storage Ambient temperature: -15oC ~ +50oC Relative humidity: no higher than 95 % Atmospheric pressure: 86 kPa ~ 106 kPa. It should be stored in a room without corrosive gas and well ventilated Package packaging box comply with the requirement of GB/T 15464 Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation Moisture protection and rain protection to ensure that product is protected from natural damage. Safty & Alarm Gas source pressure Immediate alarm; “high level alarm” indicator flickers raising an audible alarm. Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm. Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle. Ventilation Volume Alarm Lower: 0~12L/Min; Up: 18L/ Min Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V. Power On Self Test Self test before working, assure it's working normally. STANDARD CONFIGURATIONS
Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.
Request a quote ↗