Wellview Universal Group
Laboratory Electrolyte Analyzer YSTE-E972
Request photos and details of the available configuration.
Request photos on WhatsAppRequest configuration, accessories, documentation and supply terms for this model.
Supplier technical information: confirm the configuration before purchasing.
Laboratory Electrolyte Analyzer YSTE-E972 Simple YES/NO prompted operation High accurate and long life electrode and TCO2 sensor Sleep mode to reduce reagent consumption Rapid test speed of 80 tests per hour Minimum sample volume is 60ul Individual reagent to avoid waste Option: Sample tray Parameter configuration: A K, Na, Cl B K, Na, Cl, TCO2 C K, Na, Cl, iCa, nCa, TCa, pH D K, Na, Cl,iCa, nCa, TCa, pH, TCO2, AG F K, Na, Cl, Li H K, Na, Cl, iCa, nCa, TCa, pH, Li I K, Na, Cl,iCa, nCa, TCa, pH, Li, TCO2, AG J K, Na, Cl,iCa, nCa, TCa, pH, Mg, TCO2, AG K K, Na, Cl,iCa, nCa, TCa, pH, Li, Mg, TCO2, AG Specification: Sample: serum, plasma, whole blood, cerebrospinal fluid and dilute urine Measuring speed: ≤25s Analysis Method: ion select electrode (SE) Sample volume: 60-300ul (3 parameters to 11 parameters) Sample position: 35 positions (including 1 QC) Storage: up to 10,000 test results Printer: Internal thermal printer Interface: RS232 port Working environment: Temperature: 5-40℃ Relative Humidity: ≤ 80 % Atmospheric pressure: (86~106) kPa Power supply: 220V±20V, 50-60Hz Power: ≤120W Dimension:380mm*270mm*400mm Net weight:8Kg Items Measuring Range Resolution Measuring Precision (CV%) K+ 0.5-20.0mmol/L 0.01 mmol/L ≤1.0% Na+ 15-200mmol/L 0.1 mmol/L ≤1.0% Cl- 15-200mmol/L 0.1 mmol/L ≤1.0% Ca2+ 0.1-6.0mmol/L 0.01 mmol/L ≤1.0% Li+ 0.1-5.0mmol/L 0.01 mmol/L ≤2.0% pH 4-9pH 0.01 pH ≤0.5% TCO2 2.0-70.0mmol/L 0.1 mmol/L ≤3.0% Main Features: Automatic electric potential tracking and correcting software to ensure the stable performance. Automatically detect and filter tiny bubbles to avoid clog and ensure accurate measurement. Real-time diagnostic of system working status. Waste liquid automatic detection and alarming. Automatic calibration and two-point correction to adjust slope and intercept. Wave theory flushing method and direct flushing pipe method to avoid block and crossed contamination. Power failure protection to avoid data losing, data storage could be extended to more than 20,000. Available to power off any time, therefore reduce reagent consumption, suitable for any hospitals.
Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.
Request a quote ↗