HPLC Fully Auto Glycated Hemoglobin Analyzer YSTE760H

Product image coming soonHPLC Fully Auto Glycated Hemoglobin Analyzer YSTE760H

Request photos and details of the available configuration.

Request photos on WhatsApp

Request configuration, accessories, documentation and supply terms for this model.

Supplier technical information: confirm the configuration before purchasing.

HPLC Fully Auto Glycated Hemoglobin Analyzer YSTE760H
Easy Operation
○No Sample Pre-treatment
○Fully automated operation saves time and labor
○Automatic Primary tube sampling with cap puncture
○Auto identificate the whole blood or lyse
○STAT capability
○Batch sampling offer flexibility in workflow
○3.0 Mins per sample
Easy Maintenance
○ No special tools required for daily maintenance.
○ Online Alarm message for Buffer insufficient
○ Fully modular design, if fault occurs, can find the damaged parts quickly and accurately, solve problems with fastest response.
○Superior performance LED detector, long life-span, no need pre-heat,
○Temperature range for column 5-40℃, can keep the constant temperature, the fluctuation ±0.2℃
○High stability Pump to ensure the Hemoglobin separation, Maximum withstand pressure 200kg/cm²(2900psi), pressure sensitivity, fluctuation ±5%
Superior HbA1c Accuracy
○ HbA1C Standardization-compatible according to IFCC
○The measurement result includes information of each peak and chromatogram both of which can be utilized for analysis.
○ Superior Quality chromatographic resolution to eleminate interferences.
○ It provides direct determination of stable HbA1c(SA1c) with less than 2% CVs.
QC/Calibration
○ Automatic Calibration, Can correspond to IFCC & NGSP, get reliable result.
- Building - in quality control management Simplifies quality assurance compliance
Performance
Method
HIGH pressure ion exchange liquid chromatography (HPLC)
Instrument
Fully-Auto Glycated Hemoglobin HbA1c Analyzer
Sampling system
Automatic identification system for Primary Tube & sample cup,
Primary tube with cap puncture automatically
Throughput
≤3mins per sample
Sample Tray
15 sample position, MAL1 (QC1) & MAL2 (QC2) position, ST
Sample Type
Venous Blood, Finger Peripheral Blood, or hemolyse blood
Sample Volume
5ul whole blood, or lyse blood (ratio 5ul:1000ul)
Test Range
HbA1c: 3-18%; 14-191mmol/mol, HbF:0.3-5%
Test Item
HbA1c HbF & β-Thalassemia
Heat system
Temperature range for column 5-40℃, can keep the constant temperature, the fluctuation £±0.2℃
Light system
415nm LED light, long life span, the fluctuation is £2mv per hour
Printer
57nm Thermal printer, printing test curve and report
USB Port
Support LIS system, software upgrade online, external barcode scanner optional
Barcode
External barcode scanner optional
Display
8 inch LCD colorful touch screen, 162mm´122mm,
display real-time testing curve
Data Storage
more than 10,000 test reports storage (including Curve),Inquiry freely
Language
English, Spanish, Russians, Portuguese, Japanese……
Report
NGSP, IFCC result
HbA1a, HbF, HbA1c, HbA0,HbA2 variant sample report.
Optional PC software for regular report format
Work Condition
Temperature 5℃~30℃, Relative humidity 30%~75%
Power supply
110V-220V, 50-60Hz
Dimension
460mm×445mm×390mm
Weight
28KGS
Precision
Within-Run(n=20)
Inter-Run(n=20)
Low
High
Low
High
Mean
5.56
10.24
5.64
10.18
SD
0.08
0.09
0.12
0.15
CV(%)
1.43
0.87
2.13
1.47
Comparative Test

Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.