Wellview Universal Group
Gas Chromatography Analyzer YSTE-GC112N
Request configuration, accessories, documentation and supply terms for this model.
Supplier technical information: confirm the configuration before purchasing.
YSTE-GC112N Gas chromatography analyzer is one of widely used analytical instruments. It has become an ideal analytical instrument for separation or analysis in various fields. Technical Features ● Standard PC control software, built-in chromatographic workstation, achieve PC side reverse control and touch screen synchronous bidirectional control. ● 7-inch color touch screen, carrier/hydrogen/air channel flow (pressure) digital display. ● Gas shortage alarm protection function; Heating control protection function (when opening the door of the column box, the motor of the column box fan and the heating system will shut down automatically). ● Split flow/split ratio can be automatically controlled to save carrier gas. ● Configure automatic sampler installation and positioning interface to match automatic sampler of various specifications. ● The multi-core, 32-bit embedded hardware system ensures the reliable operation of the instrument. ● One-button start function, with 20 groups of sample test mode memory function. ● Using logarithmic amplifier, detection signal no cut-off value, good peak shape, extensible synchronous external trigger function, can be started by external signals (automatic sampler, thermal analyzer, etc.) at the same time the host and workstation. ● It has perfect system self-check function and fault automatic identification function. ● With 8 external event extension function interface, can be selected with various function control valves, and according to their own set time sequence work. ● RS232 communication port and LAM network port, and the configuration of data acquisition card. Oven ● Content product: 22L ● Temperature control range: 5℃ ~ 400℃ at room temperature ● Temperature control accuracy: ±0.1℃ ● Heating rate: 0.1 ~ 60℃ / min ● Program temperature rise order: 9 ● Program heating repeatability: ≤ 2% ● Cooling way: open the door after ● Cooling speed: ≤10 mins (250℃ ~ 50℃) Control Software Function ● Column temperature box control ● Control detector ● Injector control ● Map display Sampler Injector ● Temperature control range: 7℃ ~ 420℃ at room temperature ● Temperature control method: independent temperature control ● Carrier gas flow control mode: constant pressure ● Number of simultaneous installations: 3 at most ● Type of injection unit: filling column, shunt ● Split ratio: split ratio display ● Cylinder pressure range: 0 ~ 400kPa ● Cylinder pressure control accuracy: 0.1kPa ● Flow setting range: H2 0 ~ 200ml / min N2 0 ~ 150ml / min Detector ● FID, TCD optional ● Temperature control: Max. 420℃ ● Number of simultaneous installations: 2 at most ● Ignition function: automatic ● Hydrogen flame ionization detector (FID) Detection limit: ≤ 3×10-12 g/s (n-hexadecane) Baseline noise: ≤ 5× 10-14A Baseline drift: ≤ 6× 10-13A Dynamic range: 107 RSD: 3% or less ● Thermal conductivity detector (TCD) : Sensitivity: 5000mV•mL/mg (n-cetane) Baseline noise: ≤ 0.05 mV Baseline drift: ≤ 0.15mV / 30min Dynamic range: 105 ● Supply voltage: AC220V±22V, 50Hz±0.5Hz ● Power: 3000W Optional ● N2000 chromatography workstation ● Packed column ● Capillary column
Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.
Request a quote ↗