Wellview Universal Group

Digital Display Anesthesia Machine YSAV601B

Product image coming soonDigital Display Anesthesia Machine YSAV601B

Request photos and details of the available configuration.

Request photos on WhatsApp

Request configuration, accessories, documentation and supply terms for this model.

Supplier technical information: confirm the configuration before purchasing.

YSAV601B Feature
1. The high-precision Vaporizer is designed with a stable concentration output and automatic compensation for pressure, temperature, and flow rate. It can choose one of four gases: halothane, Enflurane, Isoflurane, or Sevoflurane, ensuring a successful anesthesia operation.
2. Reliable pneumatic transmission system.
3. Economic and proper configuration of technologies, optional as required by the Customer.
4. Modularized design and upgrading. Upgrading is available as required by the Customer.
YSAV601B Specification
Main body
High-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of application
adult, child
Gas source
O2: 0.27~0.55MPa
Flow meter
O2: 0.1~2L/min 2.5~10L/min
Flow rate of rapid oxygen supply
25~75L/min
Low oxygen pressure alarm
There will be sound alarm when the oxygen
pressure < 0.2MPa
Vaporizer
It has the function of automatic compensation based on pressure,
temperature,and flow rate.The regulation range of evaporator
concentration is 0~5 vol%.
Among Halothane,Enflurane,Isoflurane and Sevoflurane,
one can be chosen for application as required by the customer.
Respiratory circuit
working mode: all-close, semi-close, semi-open
releasing pressure: 0.5~7 kPa
Respiratory bellows
bellows for adults, bellows for children
tidal volume range: 0 ~ 1500 ml
Ventilator
Display mode
High-definition 4.8” LCD screen display
Ventilation mode
IPPV, MANUAL (Manual monitoring of tidal
volume, ventilation volume, respiratory rate)
Ventilation parameters
Tidal volume 50 ~ 1500ml
Rate 2~99 bpm
SIMV rate 2~20 bpm
I:E 2:1~1:8
Inspiratory trigger pressure -1.0~2.0 kPa
Pressure range 1.0~6.0 kPa
Parameters for ventilation monitoring
tidal volume, ventilation volume, IPPV rate,
I/E, peak pressure of airway, inspiratory
trigger pressure, pressure - time waveform
Security Alarm System
Airway pressure alarm
upper limit setting range 1.0~6.0 kPa
low limit setting range 0.4~2.0 kPa
Per-minute ventilation volume alarm
upper limit setting range 3.0~30L/min
low limit setting range 1.0~10L/min
Sustained high-pressure alarm
it will give alarm when stress have consistently
been higher than 2.5 kPa
Suffocation alarm
it will give sound and light alarm if there is
no tidal volume input in 15s
Power alarm
Power
AC 220V±10% 50Hz±1Hz

Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.

Request a quote ↗