Wellview Universal Group
Digital Display Anesthesia Machine YSAV601B
Request photos and details of the available configuration.
Request photos on WhatsAppRequest configuration, accessories, documentation and supply terms for this model.
Supplier technical information: confirm the configuration before purchasing.
YSAV601B Feature 1. The high-precision Vaporizer is designed with a stable concentration output and automatic compensation for pressure, temperature, and flow rate. It can choose one of four gases: halothane, Enflurane, Isoflurane, or Sevoflurane, ensuring a successful anesthesia operation. 2. Reliable pneumatic transmission system. 3. Economic and proper configuration of technologies, optional as required by the Customer. 4. Modularized design and upgrading. Upgrading is available as required by the Customer. YSAV601B Specification Main body High-strength engineering plastic rack, light, beautiful and corrosion resistant Scope of application adult, child Gas source O2: 0.27~0.55MPa Flow meter O2: 0.1~2L/min 2.5~10L/min Flow rate of rapid oxygen supply 25~75L/min Low oxygen pressure alarm There will be sound alarm when the oxygen pressure < 0.2MPa Vaporizer It has the function of automatic compensation based on pressure, temperature,and flow rate.The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,Enflurane,Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. Respiratory circuit working mode: all-close, semi-close, semi-open releasing pressure: 0.5~7 kPa Respiratory bellows bellows for adults, bellows for children tidal volume range: 0 ~ 1500 ml Ventilator Display mode High-definition 4.8” LCD screen display Ventilation mode IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate) Ventilation parameters Tidal volume 50 ~ 1500ml Rate 2~99 bpm SIMV rate 2~20 bpm I:E 2:1~1:8 Inspiratory trigger pressure -1.0~2.0 kPa Pressure range 1.0~6.0 kPa Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure - time waveform Security Alarm System Airway pressure alarm upper limit setting range 1.0~6.0 kPa low limit setting range 0.4~2.0 kPa Per-minute ventilation volume alarm upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min Sustained high-pressure alarm it will give alarm when stress have consistently been higher than 2.5 kPa Suffocation alarm it will give sound and light alarm if there is no tidal volume input in 15s Power alarm Power AC 220V±10% 50Hz±1Hz
Specifications are sourced from the authorized supplier catalog and must be confirmed for the quoted configuration. Regulatory documentation is verified by model and destination country.
Request a quote ↗